Mon-Fri from 9:00 to 18:00
Sat-Sun Closed
Contact us
Catalog
Main menu
Catalog

Do you have any questions about the product?
We will be happy to answer them in messengers

Motor (output) choke 490A, 380V, 220 kW, 0.014 mH (OCL-0490-014U-0.4SA)

In Stock In Stock
Product Code:
SPLC-OCL-0490-014U-0.4SA
Brand:
Specialist
50 394,78 UAH
Qty:

Do you have any questions about the product?
We will be happy to answer them in messengers

Delivery of goods
More details
New Post Office and address
New Post Office and address

≈ 250 UAH / Free for orders over 5,000 UAH

2-4 days
By courier in Ukraine
By courier in Ukraine

≈ 350 UAH / Free for orders over 5,000 UAH

1-2 days
Pickup from our warehouse
Pickup from our warehouse

Free

Today, after 2:00 PM
Payment
More details
Visa Mastercard Liqpay Monobank

Technical specifications

Delivery time
60 днів

Description

Three-phase motor choke 490A, 380V, 220 kW, 0.014 mH OCL-0490-014U-0.4SA are installed at the output of a frequency converter to filter the current supplied to three-phase electric motors at 380 V. The purpose of the output electric choke is as follows:

  • Creating inductive resistance that limits the power supply current to the motor, thus preventing overload and damage;
  • Preventing sudden current surges during motor start-up, which can lead to equipment failure;
  • Clearing the current sine wave from unwanted high harmonics (high-frequency noises) arising in the drive.

Use an AC output choke in the circuit between the frequency converter and the asynchronous electric motor to improve the quality of the drive's power supply, as well as ensure safe and long-term equipment operation.

Technical specifications of motor output choke OCL-0490-014U-0.4SA
Operating Voltage 3 phases 380 V
Voltage Drop 1% for 380 V (less than 4%)
Operating Frequency 50/60 Hz
Operating Current 490 A
Maximum Current may exceed operating no more than 150% for 60 s
Inductance 0.014 mH
Insulation Class F, H
Protection Class IP00 - IP22
Noise ≤65 dB
Temperature Rise ≤85 K
Dielectric Strength AC 3000 V/50 Hz/5 mA/10 s
Insulation Resistance 100 VDC, ≤100 MΩ
Ambient Operating Temperature -25 ~ +45℃
Operating Conditions of Motor Choke (Line Reactor) OCL-0490-014U-0.4SA
  • In the temperature range from minus 10 to 45℃ the choke's nominal parameters are tabulated. At temperatures above 55℃, the nominal current decreases by approximately 2% for each additional +1℃.
  • Altitude should not exceed 2000 m above sea level.
  • Humidity less than 90%.
  • Environment: free from harmful gases, flammable items, with good ventilation present.

When placing the choke in a cabinet, ensure ventilation for adequate equipment cooling.