Mon-Fri from 9:00 to 18:00
Sat-Sun Closed
Contact us
Catalog
Main menu
Catalog

Do you have any questions about the product?
We will be happy to answer them in messengers

Motor (output) choke 390A, 380V, 185 kW, 0.018 mH (OCL-0390-018U-0.4SA)

In Stock In Stock
Product Code:
SPLC-OCL-0390-018U-0.4SA
Brand:
Specialist
36 844,50 UAH
Qty:

Do you have any questions about the product?
We will be happy to answer them in messengers

Delivery of goods
More details
New Post Office and address
New Post Office and address

≈ 250 UAH / Free for orders over 5,000 UAH

2-4 days
By courier in Ukraine
By courier in Ukraine

≈ 350 UAH / Free for orders over 5,000 UAH

1-2 days
Pickup from our warehouse
Pickup from our warehouse

Free

Today, after 2:00 PM
Payment
More details
Visa Mastercard Liqpay Monobank

Technical specifications

Delivery time
60 днів

Description

Three-phase motor choke 390A, 380V, 185 kW, 0.018 mH OCL-0390-018U-0.4SA is installed on the output of the frequency converter for current filtering supplied to three-phase electric motors 380 V. The purpose of the output electric choke is as follows:

  • Creation of inductive resistance, which limits the motor supply current, thus preventing overload and damage;
  • Preventing sudden current surges during motor startup, which can lead to equipment failure;
  • Cleaning current sine wave from unwanted high harmonics (high-frequency noise) that occur in the electric drive.

Use the AC output choke in the circuit between the inverter and the asynchronous electric motor to improve drive power quality and ensure safe and long-term operation of the equipment.

Technical characteristics of the motor output choke OCL-0390-018U-0.4SA
Operating Voltage 3 phases 380 V
Voltage Drop 1% for 380 V (less than 4%)
Operating Frequency 50/60 Hz
Operating Current 390 A
Maximum Current may exceed operational by no more than 150% for 60 s
Inductance 0.018 mH
Insulation Class F, H
Protection Class IP00 - IP22
Noise ≤65 dB
Temperature Rise ≤85 k
Dielectric Strength AC 3000 V/50 Hz/5 mA/10 s
Insulation Resistance 100 VDC, ≤100 MΩ
Environmental Operating Temperature -25 ~ +45℃
Operating Conditions of Motor Choke (Line Reactor) OCL-0390-018U-0.4SA
  • Within the temperature range from minus 10 to 45℃, the nominal choke parameters are as per the table. At temperatures above 55℃, the nominal current decreases by about 2% for each additional +1℃.
  • Altitude above sea level should not exceed 2000 m.
  • Air humidity less than 90%.
  • Environment: without harmful gases, flammable objects, good ventilation present.

When placing the choke in a cabinet, ensure ventilation for sufficient equipment cooling.