Mon-Fri from 9:00 to 18:00
Sat-Sun Closed
Contact us
Catalog
Main menu
Catalog

Do you have any questions about the product?
We will be happy to answer them in messengers

Motor (output) choke 60A, 380V, 22 kW, 0.12 mH (OCL-0060-0M12-0.4SC)

In Stock In Stock
Product Code:
SPLC-OCL-0060-0M12-0.4SC
Brand:
Specialist
10 809,78 UAH
Qty:

Do you have any questions about the product?
We will be happy to answer them in messengers

Delivery of goods
More details
New Post Office and address
New Post Office and address

≈ 250 UAH / Free for orders over 5,000 UAH

2-4 days
By courier in Ukraine
By courier in Ukraine

≈ 350 UAH / Free for orders over 5,000 UAH

1-2 days
Pickup from our warehouse
Pickup from our warehouse

Free

Today, after 2:00 PM
Payment
More details
Visa Mastercard Liqpay Monobank

Technical specifications

Delivery time
60 днів

Description

Three-phase motor choke 60A, 380V, 22 kW, 0.12 mH OCL-0060-0M12-0.4SC is installed at the output of the frequency converter to filter the current supplied to the 380V three-phase electric motors. The function of the output electric choke is as follows:

  • Creates inductive resistance that limits the motor supply current, thereby preventing overload and damage;
  • Prevents sharp current surges during motor start-up, which can damage equipment;
  • Cleans the current sinusoid from unwanted high harmonics (high-frequency noises) occurring in the electric drive.

Use an AC output choke in the circuit between the converter and asynchronous electric motor to improve power supply quality for the drive, as well as safe and long-term operation of the equipment.

Technical specifications of the motor output choke OCL-0060-0M12-0.4SC
Operating voltage 3 phases 380 V
Voltage drop 1% for 380 V (less than 4%)
Operating frequency 50/60 Hz
Operating current 60 A
Maximum current can exceed operating by no more than 150% for 60 s
Inductance 0.12 mH
Insulation class F, H
Protection class IP00 - IP22
Noise ≤65 dB
Temperature rise ≤85 K
Dielectric strength AC 3000 V/50 Hz/5 mA/10 s
Insulation resistance 100 VDC, ≤100 MΩ
Operating ambient temperature -25 ~ +45℃
Operating conditions of motor choke (line reactor) OCL-0060-0M12-0.4SC
  • In the temperature range from minus 10 to 45℃ the nominal parameters of the choke are tabular. At temperatures above 55℃, the nominal current decreases by approximately 2% for each additional +1℃.
  • The altitude above sea level should not exceed 2000 m.
  • Air humidity less than 90%.
  • Environment: free from harmful gases, flammable objects, with good ventilation.

When installing the choke in a cabinet, provide ventilation for sufficient cooling of the equipment.