Mon-Fri from 9:00 to 18:00
Sat-Sun Closed
Contact us
Catalog
Main menu
Catalog

Do you have any questions about the product?
We will be happy to answer them in messengers

Motor (output) choke 600A, 380V, 280 kW, 0.012 mH (OCL-0600-012U-0.4SA)

In Stock In Stock
Product Code:
SPLC-OCL-0600-012U-0.4SA
Brand:
Specialist
53 287,50 UAH
Qty:

Do you have any questions about the product?
We will be happy to answer them in messengers

Delivery of goods
More details
New Post Office and address
New Post Office and address

≈ 250 UAH / Free for orders over 5,000 UAH

2-4 days
By courier in Ukraine
By courier in Ukraine

≈ 350 UAH / Free for orders over 5,000 UAH

1-2 days
Pickup from our warehouse
Pickup from our warehouse

Free

Today, after 2:00 PM
Payment
More details
Visa Mastercard Liqpay Monobank

Technical specifications

Delivery time
60 днів

Description

Three-phase Motor Choke 600A, 380V, 280 kW, 0.012 mH OCL-0600-012U-0.4SA is installed at the output of the frequency converter to filter the current supplied to 380 V three-phase electric motors. The purpose of the output electric choke is as follows:

  • Creation of inductive resistance that limits the motor's power supply current, thus preventing overload and damage;
  • Prevention of sharp current spikes during motor startup that may cause equipment failure;
  • Cleansing the current waveform from unwanted high harmonics (high-frequency noise) inherent in electric drives.

Use the AC output choke in the circuit between the frequency converter and the asynchronous motor to enhance the power supply quality of the drive, as well as to ensure safe and long-term operation of the equipment.

Technical Specifications of the Motor Output Choke OCL-0600-012U-0.4SA
Operating Voltage 3 Phases 380 V
Voltage Drop 1% for 380 V (less than 4%)
Operating Frequency 50/60 Hz
Operating Current 600 A
Maximum Current may exceed operating by no more than 150% for 60 s
Inductance 0.012 mH
Insulation Class F, H
Protection Class IP00 - IP22
Noise ≤65 dB
Temperature Rise ≤85 K
Dielectric Strength AC 3000 V/50 Hz/5 mA/10 s
Insulation Resistance 100 VDC, ≤100 MΩ
Operating Ambient Temperature -25 ~ +45℃
Operating Conditions for the Motor Choke (Line Reactor) OCL-0600-012U-0.4SA
  • At temperature ranges from minus 10 to 45℃, choke ratings are tabular. When temperature exceeds 55℃, the rated current decreases by approximately 2% for each additional +1℃.
  • Altitude not exceeding 2000 m above sea level.
  • Air humidity less than 90%.
  • Environment: free from harmful gases, flammable items, presence of good ventilation.

When placing the choke in a cabinet, ensure ventilation for adequate cooling of the equipment.