Mon-Fri from 9:00 to 18:00
Sat-Sun Closed
Contact us
Catalog
Main menu
Catalog

Do you have any questions about the product?
We will be happy to answer them in messengers

Motor (output) choke 200A, 380V, 75 kW, 0.035 mH (OCL-0200-035U-0.4SA)

In Stock In Stock
Product Code:
SPLC-OCL-0200-035U-0.4SA
Brand:
Specialist
25 121,28 UAH
Qty:

Do you have any questions about the product?
We will be happy to answer them in messengers

Delivery of goods
More details
New Post Office and address
New Post Office and address

≈ 250 UAH / Free for orders over 5,000 UAH

2-4 days
By courier in Ukraine
By courier in Ukraine

≈ 350 UAH / Free for orders over 5,000 UAH

1-2 days
Pickup from our warehouse
Pickup from our warehouse

Free

Today, after 2:00 PM
Payment
More details
Visa Mastercard Liqpay Monobank

Technical specifications

Delivery time
60 днів

Description

Three-phase motor choke 200A, 380V, 75 kW, 0.035 mH OCL-0200-035U-0.4SA is installed at the output of a frequency converter for filtering current supplied to three-phase electric motors of 380 V. The purpose of the output electrical choke is as follows:

  • Creating inductive resistance, which limits the motor supply current, thereby preventing its overload and damage;
  • Preventing sharp current surges during motor start, which can lead to equipment failure;
  • Cleaning the current sine wave from unwanted high harmonics (high-frequency noise) that occur in the drive.

Use the AC output choke in the circuit between the frequency converter and the asynchronous electric motor to improve the quality of the drive power supply, as well as for safe and long-term operation of the equipment.

Technical specifications of the motor output choke OCL-0200-035U-0.4SA
Operating voltage 3 phases 380 V
Voltage drop 1% for 380 V (less than 4%)
Operating frequency 50/60 Hz
Operating current 200 A
Maximum current may exceed the operating by no more than 150% for 60 s
Inductance 0.0035 mH
Insulation class F, H
Protection class IP00 - IP22
Noise ≤65 dB
Temperature rise ≤85 k
Dielectric permeability AC 3000 V/50 Hz/5 mA/10 s
Insulation resistance 100 VDC, ≤100 MΩ
Ambient operating temperature -25 ~ +45℃
Operating conditions for the motor choke (linear reactor) OCL-0200-035U-0.4SA
  • In the temperature range from minus 10 to 45℃, the nominal choke parameters are tabular. At temperatures above 55℃, the nominal current decreases by approximately 2% with each additional +1℃.
  • The altitude above sea level should not exceed 2000 m.
  • Air humidity less than 90%.
  • Environment: free from harmful gases, flammable items, with good ventilation.

When placing the choke in a cabinet, ensure ventilation for sufficient cooling of the equipment.

Read more

Reviews (0)

0
rating rating rating rating rating

based on 0 reviews

Average rating of our customers