Motor (output) choke 120A, 380V, 45 kW, 0.058 mH (OCL-0120-058U-0.4SA)

In Stock In Stock
Product Code:
SPLC-OCL-0120-058U-0.4SA
Brand:
Specialist
20 097,00 UAH
Qty:

Do you have any questions about the product?
We will be happy to answer them in messengers

Delivery of goods
More details
New Post Office and address
New Post Office and address

≈ 250 UAH / Free for orders over 5,000 UAH

2-4 days
By courier in Ukraine
By courier in Ukraine

≈ 350 UAH / Free for orders over 5,000 UAH

1-2 days
Pickup from our warehouse
Pickup from our warehouse

Free

Today, after 2:00 PM
Payment
More details
Visa Mastercard Liqpay Monobank

Technical specifications

Delivery time
60 днів

Description

Three-phase motor choke 120A, 380V, 45kW, 0.058mH OCL-0120-058U-0.4SA is installed at the output of a frequency converter to filter the current supplied to three-phase electric motors 380V. The purpose of the output electric reactor is as follows:

  • Creates inductive resistance, which limits the motor's supply current, thus preventing overload and damage;
  • Prevents sharp current spikes during motor start-up, which can damage equipment;
  • Cleans current sinewave of undesirable high harmonics (high-frequency noises) that arise in the electric drive.

Use the AC output choke in the circuit between the frequency converter and the asynchronous motor to improve power supply quality and ensure safe and long-term equipment operation.

Technical characteristics of the motor output choke OCL-0120-058U-0.4SA
Operating Voltage 3 Phases 380 V
Voltage Drop 1% for 380V (less than 4%)
Operating Frequency 50/60 Hz
Operating Current 120 A
Maximum Current may exceed operating no more than 150% for 60 s
Inductance 0.058 mH
Insulation Class F, H
Protection Class IP00 - IP22
Noise ≤65 dB
Temperature Rise ≤85 K
Dielectric Strength AC 3000 V/50 Hz/5 mA/10 s
Insulation Resistance 100 VDC, ≤100 MΩ
Ambient Operating Temperature -25 ~ +45℃
Operating Conditions of the Motor Choke (Line Reactor) OCL-0120-058U-0.4SA
  • In the temperature range from minus 10 to 45℃, nominal choke parameters are tabulated. At temperatures above 55℃, nominal current reduces by approximately 2% for each additional +1℃.
  • Altitude above sea level should not exceed 2000 m.
  • Air humidity less than 90%.
  • Environment: free from harmful gases, flammable substances, with good ventilation.

When placing the choke in a cabinet, ensure ventilation for sufficient cooling of the equipment.